The effect of electro-hydrodynamic shockwaves on the quality of striploin and brisket beef muscles during long-term storageExport / Share PlumX View Altmetrics View AltmetricsMcDonnell, C. K., Fitzgerald, A. G., Burt, P., Hughes, J., Mellor, G. E., Barlow, R. S., Sikes, A. L., Li, Y. and Tobin, A. B. (2021) The effect of electro-hydrodynamic shockwaves on the quality of striploin and brisket beef muscles during long-term storage. Innovative Food Science & Emerging Technologies, 68 . p. 102627. ISSN 1466-8564
Article Link: https://doi.org/10.1016/j.ifset.2021.102627 Publisher URL: https://www.sciencedirect.com/science/article/pii/S146685642100028X AbstractShockwaves generate instantaneous high pressures, which could affect meat shelf-life or quality. This study assessed microbiological counts, pH, drip, cook and moisture loss and texture of striploin (longissimus lumborum) and brisket (pectoralis profundus) treated with electrical shockwave (25 kV, 8 pulses) and subsequently stored (−0.5 °C) for 0, 4, 8, 12, 16 and 20 weeks. Shockwave did not affect total viable counts (p>0.05), with all samples considered microbiologically acceptable (<7 log10 CFU/cm2) after 20 weeks. Shockwave reduced the peak force of striploin by 14.4% (5.8 N) (p<0.001). However, for brisket, there was no effect of shockwave on texture (p>0.05). Shockwave × storage time increased moisture losses in striploin (p<0.01) and brisket (p<0.01) at week 0 but this decreased over subsequent storage weeks. Shockwave technology did not affect meat shelf-life and has potential for beef tenderisation.
Repository Staff Only: item control page Download Statistics DownloadsDownloads per month over past year |