Evaluation of the API 20E and Microbact 24E systems for the identification of Pseudomonas pseudomalleiExport / Share PlumX View Altmetrics View AltmetricsThomas, A. D. (1983) Evaluation of the API 20E and Microbact 24E systems for the identification of Pseudomonas pseudomallei. Veterinary Microbiology, 8 (6). pp. 611-615. Full text not currently attached. Access may be available via the Publisher's website or OpenAccess link. Article Link: http://dx.doi.org/10.1016/0378-1135(83)90009-3 Publisher URL: http://www.elsevier.com AbstractOne hundred isolates of Pseudomonas pseudomallei were used to evaluate the API 20E and Microbact 24E rapid identification systems. The API 20E system identified 50% of the isolates using the revised 1979 Manual only, and 63% when referral was made to the computer centre. A higher identification rate (69 and 87%, respectively) was achieved with a longer incubation period of 96 h. The Microbact 24E system identified 84% of the isolates as Ps. pseudomallei using the revised 1983 Manual, and 100% when referral was made to the computer centre. The Microbact 24E system would appear to be a reliable system for the identification of Ps. pseudomallei.